APPLICATIONS:
Condensate from condensing boilers is acidic (pH between 2.5 and 5 depending on the fuel type). The condensate neutralisers contain a neutralising agent that eliminates the acidity of the condensate before it is discharged into the drain. It is designed for wall-mounted boilers up to 35 kW and is supplied with a neutralising charge.
BWT Condensates 0–35 kW:
- Suitable for all individual boilers up to 35 kW
- Ideal for individual housing in collective buildings
- Ergonomic design: can be installed on drainage or piping. (Mounting collar included)
- Refill frequency: 1 year or more
- Overflow protection system included
MAINTENANCE
The neutralising charge should be replaced when depleted, or ideally once a year to prevent excessive clogging of the device.
To check and maintain the proper functioning of your Condensate Neutraliser:
- Periodically, check the pH of the outgoing water using a pH strip (the pH should be above 6.5).
- If pH is below 6.5 please check the level of the neutraliser (white granules) inside and top up if necessary.
- Clean the device with each neutralising charge replacement. Rinsing the granules can help extend the lifespan and effectiveness of the neutralising charge.